Add to Cart
Cables Flammability Testing Equipment SL-7603C Single Cable Vertical Flaming Tester
Standards
According to IEC60332-1-1:2004, IEC60332-1-2:2004, IEC60332-1-3:2004, EN50265-1, EN50265-2-1
Application
Applies to check thesingle insulation wire and cable vertical spreading test which total section area less than 0.5mm2
Technical parameters
| Vertical burning chamber | W300xH1200xD450mm | 
| Gas | Use high purity propane gas or liquefied petroleum gas (provide by user-self) | 
| Specimen length | 600±25mm | 
| Area of specimen | Total section area less than 0.5mm2 | 
| Testing temperature | This device is located in a stuffiness room and the temperature keeping the 23±10℃ for testing | 
| Burning time | continuously setting between 0.1-999.9S, during the setting time flame could continuously burning the specimen | 
| Control function | Switch can choose to be manual or automatically according to the actual needed | 
| Gas flow range | 0.1-1L/min | 
| Area flow range | 0.1-1m3/h | 
| Burner | 500W for standards power, 125±25mm for total height of the flame | 
| Temperature measurement system | according to GB/T5169.14-2007 and IEC60695-11-03 standard requirements, including temperature copper (10g), K type thermocouple and diameter is 0.5 mm with stainless steel sheathed, stopwatch and thermometer etc. | 