Skyline Instruments Co.,LTD

Skyline Instruments Co.,LTD

Manufacturer from China
Active Member
9 Years
Home / Products / Electronic Testing Equipment /

Electronic Test Equipment IEC60695-5-10 Glow Wire Testing Equipment

Contact Now
Skyline Instruments Co.,LTD
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MsYu
Contact Now

Electronic Test Equipment IEC60695-5-10 Glow Wire Testing Equipment

Ask Latest Price
Brand Name :SKYLINE
Model Number :SL-E04
Certification :CE
Place of Origin :CHINA
MOQ :1 UNIT
Payment Terms :TT , Western Union,paypal
Supply Ability :100 pcs /week
Delivery Time :10 working days
Packaging Details :Plywood case
Price :Negoitable
SKYLINE :Glow Wire Test Chamber
Standard :IEC60695-5-10
Temperature Range :500 ~ 750℃±10℃;750 ~ 960℃±15℃
Ironing Into Depth :7mm ± 0.5 Mm
Glow-wire Into And Through The Test Specimen :7 Mm ± 0,5 Mm.
Force To The Test Specimen :0,95 N ± 0,10 N
Volume Of Chamber :0.5m3
Material :Steel
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Electronic Test Equipment IEC60695-5-10 Glow Wire Testing Equipment


Product Introduction
• The Glow Wire Tester is designed to carry out fire hazard testing on electro technical products in accordance with the provisions of International standards.
• The control unit is supplied with all the controls and metering necessary to accurately set the temperature of the glow wire. The wire current is continuously variable by means of the panel-mounted controller and is monitored by the built-in ammeter.
• A digital temperature indicator is fitted which, in conjunction with the thermocouple supplied, accurately measures the glow wire temperature. The electrical circuit of the control unit is fully protected by fuses and a miniature circuit breaker and incorporates mains on/off switching and push button control of the output current. Self contained cabinet with large viewing window and dark colored interior.

Technical parameters

Glow wire diameter 4mm±0.04mmNi/Cr(80/20)
Temperature range 500 ~ 750℃±10℃;750 ~ 960℃±15℃
Thermocouple diameter 0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand temperature-40~ 1100°C
Searing Time 30s±0.1s (OMRON H5CN-XAN-Z digital timer, 0-9999s, preset table)
Light-off Time 0-999.9 s ± 0.1 s, automatic recording, manual timeout
Fire out time 0-999.9 s ± 0.1 s, automatic recording, manual timeout
Ironing into depth 7mm ± 0.5 mm
Sample pressure 1N ± 0.2 N
Test speed 18±3mm/s
Test background black background
Test process automatic control independent convulsions
Chamber ≥0.5m
Control Using single chip microcomputer + touch screen control
Power Supply AC 220V,50Hz


Glow-wire
Glow-wire material: Nickel/Chromium (>77 %Ni/20 ± 1 %Cr)
Diameter: 4,0 mm ± 0,07 mm (before bending)
A new glow-wire shall be annealed for a total of at least 10 h by being subjected to a current of at least 120 A before being used for a test run. The total annealing time may be achieved cumulatively. To avoid damage, the thermocouple shall not be installed during annealing. At the end of annealing, the depth of the thermocouple pocket hole shall be verified.
Timer 0-30s ±1s
Force to the test specimen 0,95 N ± 0,10 N
glow-wire into and through the test specimen 7 mm ± 0,5 mm.
Speed 10 mm/s to 25 mm/s
fine-wire thermocouple nominal diameter of 1,0 mm. The thermocouple wires shall be suitable for continuous operation at temperatures up to 960 °C (e.g. chromel/alumel (Type K) – see IEC 60584-1). The welded point shall be located inside the sheath as close to the tip as
practicable. The sheath shall consist of a metal resistant to continuous operation at a temperature of at least 1 050 °C.
Temperature range 500-1000C°
Chamber having a volume of at least 0,5 m3 , dark background, illumination £ 20 lx.
Initial calibration report: Required. And shall include the Temperature vs current chart in the report also
wooden board (x2) flat and smooth and having a minimum thickness of 10 mm


Standards
IEC60695 - 2 - 10 / 11 / 12 / 13,IEC60884-1,IEC60335-1,VDE0620

Inquiry Cart 0